📋 EXAMPLE REPORT This is a sample. Real PARs are tied to live GPS jobs.
← View all 10 examples
✅ CERTIFIED REPORT
📋 EXAMPLE
🌿 EPA BMP
Environmental Compliance & BMP Audit
Example Certified Post-Action Report · Florida FDEP NPDES MS4 FLR04E018
CPAR-EX-004
Saturday, April 18, 2026
Brick & Mortar Exterior
Sunshine Exterior Services
9,800 sqft
27.94680, -82.45840
✅ Certified
4 Pillars of Compliance 📋 Chemical Log ✓ · 📸 Photos ✓ · 🧪 pH Log ✓ · ⏱ Surface + Method ✓ · 💧 Water Recovery ✓
📍

Job Details

Site address, surface type, crew & GPS coordinates
01
Property Address📍 800 E Twiggs St, Tampa, FL 33602
Surface TypeBrick & Mortar Exterior
Job DateSaturday, April 18, 2026
Crew Name👷 Sunshine Exterior Services
Area Cleaned9,800 sqft
Dwell Time⏱ 12 minutes
Permit🌿 FDEP NPDES MS4 FLR04E018
Permit AuthorityFlorida DEP Stormwater Section
GPS Coordinates📡 27.94680, -82.45840 ✓ Captured
Report GeneratedApril 18, 2026
📍 GPS: 27.94680, -82.45840  ·  Open in map ↗
🧪

Chemical Application Log

Products used, dilution ratios & volume documentation — SH 2.5% · Elemonator (0.5 oz/gal)
02
Chemical Product Volume Applied Notes / Dilution
Sodium Hypochlorite 12.5% (diluted to 2.5%)
⚠️ See SDS below · OSHA HazCom 2012
32.00 gal Soft wash — brick mortar sensitivity requires <3% SH concentration
Elemonator Non-ionic Surfactant
⚠️ See SDS below · OSHA HazCom 2012
3.50 gal 0.5 oz/gal to improve cling time on porous brick
🌿

pH Neutralization Log

Pre- and post-application runoff pH readings — EPA 6.0–9.0 discharge standard
03
⬆ pH Before (Baseline)
8.4
✅ pH After (Neutralized)
7.2
✅ Final pH within EPA-acceptable range (6.0–9.0). Gatekeeper: PASS.
TimeLocationpH ReadingNote
07:00 NW corner drain 8.4 Baseline — slight alkalinity from historic mortar
09:30 NW corner drain 8.0 Mid-wash
10:45 NW corner drain 7.2 Post-rinse — within FDEP 6.0–9.0 standard
💧

Wastewater Recovery

Gallons captured for proper disposal · EPA NPDES compliance
04
💧 76 gallons recovered
Gallons Recovered💧 76 gal
Disposal Method🚛 Vacuumed and transported offsite per FDEP NPDES MS4 FLR04E018 permit conditions
Compliance Note✅ Wastewater documented per NPDES requirements
📸

Job Site Photos

Before, during & after — visual compliance documentation
05
📷Before — Brick & Mortar Exterior
🔵During — Chemical application
After — Surface restored
📋 Photo placeholders shown. Real PARs include uploaded before/during/after photos stored in your account.
⚠️

Safety Data Sheets (SDS)

OSHA HazCom 2012 — product safety information for all chemicals used
06
🧪
Sodium Hypochlorite 12.5%
⚠️ HAZMAT · GHS05 (Corrosive) · GHS07 (Irritant)
⬇ Download SDS
PPE RequiredChemical-resistant gloves, safety goggles
Spill ResponseDilute with large amounts of water.
NotesHeld at 2.5% — historic brick mortar sensitivity protocol.
🫧
Elemonator Non-ionic Surfactant
⚠️ HAZMAT · GHS07 (Irritant)
⬇ Download SDS
PPE RequiredGloves, safety glasses
Spill ResponseAbsorb with inert material, rinse with water.
NotesNon-ionic surfactant. Improves dwell contact on porous brick.
🏅

SurfaceOps Certification

Compliance attestation & verification record
07
Operator Compliance Statement: The undersigned operator certifies that all information contained in this Post-Action Report is accurate and complete. Chemical products were applied in accordance with SDS guidelines and applicable EPA/state stormwater Best Management Practices. Runoff was managed per the documented disposal method, and all pH readings were recorded at time of service.
Crew / Operator
Sunshine Exterior Services
Surface Type
Brick & Mortar Exterior
Job Date
Saturday, April 18, 2026
Report Number
CPAR-EX-004
← View all 10 examples ⚡ Generate My PAR Preview (Free) →
This is a sample. Real PARs are tied to live GPS jobs and your crew's data.
Free Preview Order Your Certified PAR — $99