📋 EXAMPLE REPORT This is a sample. Real PARs are tied to live GPS jobs.
← View all 10 examples
✅ CERTIFIED REPORT
📋 EXAMPLE
🌿 EPA BMP
Environmental Compliance & BMP Audit
Example Certified Post-Action Report · Texas TCEQ TXR040000
CPAR-EX-002
Saturday, March 28, 2026
EIFS / Stucco Exterior
Texas Pro Wash LLC
18,200 sqft
29.69040, -95.48130
✅ Certified
4 Pillars of Compliance 📋 Chemical Log ✓ · 📸 Photos ✓ · 🧪 pH Log ✓ · ⏱ Surface + Method ✓ · 💧 Water Recovery ✓
📍

Job Details

Site address, surface type, crew & GPS coordinates
01
Property Address📍 7600 Beechnut St, Houston, TX 77074
Surface TypeEIFS / Stucco Exterior
Job DateSaturday, March 28, 2026
Crew Name👷 Texas Pro Wash LLC
Area Cleaned18,200 sqft
Dwell Time⏱ 10 minutes
Permit🌿 TCEQ TXR040000
Permit AuthorityTexas Commission on Environmental Quality
GPS Coordinates📡 29.69040, -95.48130 ✓ Captured
Report GeneratedMarch 28, 2026
📍 GPS: 29.69040, -95.48130  ·  Open in map ↗
🧪

Chemical Application Log

Products used, dilution ratios & volume documentation — SH 2% · Simple Cherry (0.75 oz/gal)
02
Chemical Product Volume Applied Notes / Dilution
Sodium Hypochlorite 12.5% (diluted to 2%)
⚠️ See SDS below · OSHA HazCom 2012
55.00 gal Low-pressure soft wash — EIFS requires <500 PSI to avoid coating breach
Simple Cherry Non-ionic Surfactant
⚠️ See SDS below · OSHA HazCom 2012
6.00 gal 0.75 oz/gal; cherry-scented, hospital-adjacent — minimizes odor complaints
Neutra-Wash pH Neutralizer
⚠️ See SDS below · OSHA HazCom 2012
8.00 gal Post-rinse pH correction — lowered runoff from 9.1 to 7.4
🌿

pH Neutralization Log

Pre- and post-application runoff pH readings — EPA 6.0–9.0 discharge standard
03
⬆ pH Before (Baseline)
9.1
✅ pH After (Neutralized)
7.4
✅ Final pH within EPA-acceptable range (6.0–9.0). Gatekeeper: PASS.
TimeLocationpH ReadingNote
06:30 Storm drain #3 (west lot) 9.1 Pre-wash baseline — SH residue from adjacent area
09:15 Storm drain #3 (west lot) 8.6 Mid-wash reading
11:00 Storm drain #3 (west lot) 7.4 Post neutralizer — within TCEQ 6.5–9.0 standard
💧

Wastewater Recovery

Gallons captured for proper disposal · EPA NPDES compliance
04
💧 142 gallons recovered
Gallons Recovered💧 142 gal
Disposal Method🚛 Vacuumed and transported offsite per TCEQ TXR040000 permit conditions
Compliance Note✅ Wastewater documented per NPDES requirements
📸

Job Site Photos

Before, during & after — visual compliance documentation
05
📷Before — EIFS / Stucco Exterior
🔵During — Chemical application
After — Surface restored
📋 Photo placeholders shown. Real PARs include uploaded before/during/after photos stored in your account.
⚠️

Safety Data Sheets (SDS)

OSHA HazCom 2012 — product safety information for all chemicals used
06
🧪
Sodium Hypochlorite 12.5%
⚠️ HAZMAT · GHS05 (Corrosive) · GHS07 (Irritant)
⬇ Download SDS
PPE RequiredChemical-resistant gloves, safety goggles, long sleeves
Spill ResponseDilute with large amounts of water.
NotesApplied at 2% on EIFS — low enough to avoid coating degradation.
🫧
Simple Cherry Surfactant
⚠️ HAZMAT · GHS07 (Irritant)
⬇ Download SDS
PPE RequiredGloves, safety glasses
Spill ResponseAbsorb with inert material, rinse with water.
NotesNon-ionic surfactant. Low odor formulation for hospital-adjacent jobs.
⚖️
Neutra-Wash pH Neutralizer
⚠️ HAZMAT · Non-hazmat
⬇ Download SDS
PPE RequiredGloves recommended
Spill ResponseDilute with water, mop up.
NotesCitric acid-based neutralizer. Reduces runoff pH to EPA-acceptable range.
🏅

SurfaceOps Certification

Compliance attestation & verification record
07
Operator Compliance Statement: The undersigned operator certifies that all information contained in this Post-Action Report is accurate and complete. Chemical products were applied in accordance with SDS guidelines and applicable EPA/state stormwater Best Management Practices. Runoff was managed per the documented disposal method, and all pH readings were recorded at time of service.
Crew / Operator
Texas Pro Wash LLC
Surface Type
EIFS / Stucco Exterior
Job Date
Saturday, March 28, 2026
Report Number
CPAR-EX-002
← View all 10 examples ⚡ Generate My PAR Preview (Free) →
This is a sample. Real PARs are tied to live GPS jobs and your crew's data.
Free Preview Order Your Certified PAR — $99