📋 EXAMPLE REPORT This is a sample. Real PARs are tied to live GPS jobs.
← View all 10 examples
✅ CERTIFIED REPORT
📋 EXAMPLE
🌿 EPA BMP
Environmental Compliance & BMP Audit
Example Certified Post-Action Report · North Carolina NC DEQ NPDES NCG11000
CPAR-EX-010
Sunday, March 8, 2026
EIFS / Stucco Exterior
Carolinas Pro Wash LLC
16,800 sqft
35.22710, -80.84310
✅ Certified
4 Pillars of Compliance 📋 Chemical Log ✓ · 📸 Photos ✓ · 🧪 pH Log ✓ · ⏱ Surface + Method ✓ · 💧 Water Recovery ✓
📍

Job Details

Site address, surface type, crew & GPS coordinates
01
Property Address📍 601 E 5th St, Charlotte, NC 28202
Surface TypeEIFS / Stucco Exterior
Job DateSunday, March 8, 2026
Crew Name👷 Carolinas Pro Wash LLC
Area Cleaned16,800 sqft
Dwell Time⏱ 8 minutes
Permit🌿 NC DEQ NPDES NCG11000
Permit AuthorityNC Department of Environmental Quality
GPS Coordinates📡 35.22710, -80.84310 ✓ Captured
Report GeneratedMarch 8, 2026
📍 GPS: 35.22710, -80.84310  ·  Open in map ↗
🧪

Chemical Application Log

Products used, dilution ratios & volume documentation — SH 1.5% · Elemonator (0.5 oz/gal)
02
Chemical Product Volume Applied Notes / Dilution
Sodium Hypochlorite 12.5% (diluted to 1.5%)
⚠️ See SDS below · OSHA HazCom 2012
52.00 gal School campus — low concentration required; students on-site after 3pm
Elemonator Non-ionic Surfactant
⚠️ See SDS below · OSHA HazCom 2012
5.50 gal 0.5 oz/gal; low-odor formulation for occupied school environment
🌿

pH Neutralization Log

Pre- and post-application runoff pH readings — EPA 6.0–9.0 discharge standard
03
⬆ pH Before (Baseline)
8.0
✅ pH After (Neutralized)
7.0
✅ Final pH within EPA-acceptable range (6.0–9.0). Gatekeeper: PASS.
TimeLocationpH ReadingNote
06:00 South campus drain 8.0 Baseline — slightly alkaline from painted stucco surface
09:30 South campus drain 7.6 Mid-wash
11:00 South campus drain 7.0 Post-rinse — within NC DEQ 6.0–9.0 standard
💧

Wastewater Recovery

Gallons captured for proper disposal · EPA NPDES compliance
04
💧 132 gallons recovered
Gallons Recovered💧 132 gal
Disposal Method🚛 Vacuumed and transported offsite per NC DEQ NPDES NCG11000 permit conditions
Compliance Note✅ Wastewater documented per NPDES requirements
📸

Job Site Photos

Before, during & after — visual compliance documentation
05
📷Before — EIFS / Stucco Exterior
🔵During — Chemical application
After — Surface restored
📋 Photo placeholders shown. Real PARs include uploaded before/during/after photos stored in your account.
⚠️

Safety Data Sheets (SDS)

OSHA HazCom 2012 — product safety information for all chemicals used
06
🧪
Sodium Hypochlorite 12.5%
⚠️ HAZMAT · GHS05 (Corrosive) · GHS07 (Irritant)
⬇ Download SDS
PPE RequiredChemical-resistant gloves, safety goggles, long sleeves
Spill ResponseDilute with large amounts of water.
NotesSchool campus protocol: 1.5% max, job complete before students arrive.
🫧
Elemonator Non-ionic Surfactant
⚠️ HAZMAT · GHS07 (Irritant)
⬇ Download SDS
PPE RequiredGloves, safety glasses
Spill ResponseAbsorb with inert material.
NotesLow-odor for occupied school. Cherry-scented variant available.
🏅

SurfaceOps Certification

Compliance attestation & verification record
07
Operator Compliance Statement: The undersigned operator certifies that all information contained in this Post-Action Report is accurate and complete. Chemical products were applied in accordance with SDS guidelines and applicable EPA/state stormwater Best Management Practices. Runoff was managed per the documented disposal method, and all pH readings were recorded at time of service.
Crew / Operator
Carolinas Pro Wash LLC
Surface Type
EIFS / Stucco Exterior
Job Date
Sunday, March 8, 2026
Report Number
CPAR-EX-010
← View all 10 examples ⚡ Generate My PAR Preview (Free) →
This is a sample. Real PARs are tied to live GPS jobs and your crew's data.
Free Preview Order Your Certified PAR — $99