📋 EXAMPLE REPORT This is a sample. Real PARs are tied to live GPS jobs.
← View all 10 examples
✅ CERTIFIED REPORT
📋 EXAMPLE
🌿 EPA BMP
Environmental Compliance & BMP Audit
Example Certified Post-Action Report · Georgia GA EPD NPDES GAG610000
CPAR-EX-005
Sunday, April 5, 2026
Vinyl Siding
Southern Soft Wash Pros
31 buildings
33.84900, -84.36340
✅ Certified
4 Pillars of Compliance 📋 Chemical Log ✓ · 📸 Photos ✓ · 🧪 pH Log ✓ · ⏱ Surface + Method ✓ · 💧 Water Recovery ✓
📍

Job Details

Site address, surface type, crew & GPS coordinates
01
Property Address📍 3500 Peachtree Rd NE, Atlanta, GA 30326
Surface TypeVinyl Siding
Job DateSunday, April 5, 2026
Crew Name👷 Southern Soft Wash Pros
Area Cleaned31 buildings
Dwell Time⏱ 6 minutes
Permit🌿 GA EPD NPDES GAG610000
Permit AuthorityGeorgia EPD Water Protection Branch
GPS Coordinates📡 33.84900, -84.36340 ✓ Captured
Report GeneratedApril 5, 2026
📍 GPS: 33.84900, -84.36340  ·  Open in map ↗
🧪

Chemical Application Log

Products used, dilution ratios & volume documentation — SH 1% · Simple Cherry (0.5 oz/gal)
02
Chemical Product Volume Applied Notes / Dilution
Sodium Hypochlorite 12.5% (diluted to 1%)
⚠️ See SDS below · OSHA HazCom 2012
95.00 gal Ultra-low concentration for vinyl — prevents chalking and color fade
Simple Cherry Non-ionic Surfactant
⚠️ See SDS below · OSHA HazCom 2012
9.00 gal 0.5 oz/gal; tenant-proximity job — low odor formulation required by PM
White Vinegar pH Adjustment
⚠️ See SDS below · OSHA HazCom 2012
12.00 gal Post-rinse to lower slightly elevated baseline pH from old complex
🌿

pH Neutralization Log

Pre- and post-application runoff pH readings — EPA 6.0–9.0 discharge standard
03
⬆ pH Before (Baseline)
7.8
✅ pH After (Neutralized)
7.0
✅ Final pH within EPA-acceptable range (6.0–9.0). Gatekeeper: PASS.
TimeLocationpH ReadingNote
06:15 Complex main drain outfall 7.8 Baseline — aging complex with alkaline residue in drains
11:00 Complex main drain outfall 7.4 Mid-day reading — 14 buildings complete
15:30 Complex main drain outfall 7.0 Final reading — 31 buildings complete. Within GA EPD standard.
💧

Wastewater Recovery

Gallons captured for proper disposal · EPA NPDES compliance
04
💧 290 gallons recovered
Gallons Recovered💧 290 gal
Disposal Method🚛 Vacuumed and transported offsite per GA EPD NPDES GAG610000 permit conditions
Compliance Note✅ Wastewater documented per NPDES requirements
📸

Job Site Photos

Before, during & after — visual compliance documentation
05
📷Before — Vinyl Siding
🔵During — Chemical application
After — Surface restored
📋 Photo placeholders shown. Real PARs include uploaded before/during/after photos stored in your account.
⚠️

Safety Data Sheets (SDS)

OSHA HazCom 2012 — product safety information for all chemicals used
06
🧪
Sodium Hypochlorite 12.5%
⚠️ HAZMAT · GHS05 (Corrosive) · GHS07 (Irritant)
⬇ Download SDS
PPE RequiredChemical-resistant gloves, safety goggles
Spill ResponseDilute with large amounts of water.
NotesApplied at 1% — tenant proximity required minimal concentration.
🫧
Simple Cherry Surfactant
⚠️ HAZMAT · GHS07 (Irritant)
⬇ Download SDS
PPE RequiredGloves, safety glasses
Spill ResponseAbsorb with inert material.
NotesLow-odor formulation. Tenant complaints minimized.
🏅

SurfaceOps Certification

Compliance attestation & verification record
07
Operator Compliance Statement: The undersigned operator certifies that all information contained in this Post-Action Report is accurate and complete. Chemical products were applied in accordance with SDS guidelines and applicable EPA/state stormwater Best Management Practices. Runoff was managed per the documented disposal method, and all pH readings were recorded at time of service.
Crew / Operator
Southern Soft Wash Pros
Surface Type
Vinyl Siding
Job Date
Sunday, April 5, 2026
Report Number
CPAR-EX-005
← View all 10 examples ⚡ Generate My PAR Preview (Free) →
This is a sample. Real PARs are tied to live GPS jobs and your crew's data.
Free Preview Order Your Certified PAR — $99